Worked Example
Verified calculation
Given:
- Thermal resistance of first glass pane = 0.017
- Thermal resistance of second glass pane = 0.017
- Thermal resistance of third glass pane = 0.017
- Exterior surface thermal resistance = 0.04
- Interior surface thermal resistance = 0.13
- Indoor air temperature = 294.15
- Outdoor air temperature = 268.15
Expected Result:
- Inner surface temperature of triple glazing = 272.85588235294
Engineering Interpretation:
Under the given input conditions, the calculated result is: Inner surface temperature of triple glazing = 272.85588235294 K.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
inner surface temperature of triple glazing = indoor air temperature - (indoor air temperature - outdoor air temperature) * (interior surface thermal resistance + thermal resistance of first glass pane + thermal resistance of second glass pane + thermal resistance of third glass pane) / (interior surface thermal resistance + thermal resistance of first glass pane + thermal resistance of second glass pane + thermal resistance of third glass pane + exterior surface thermal resistance)Formula family: formula_buildingphysics_triple_glazing_surface_temperature_calculator
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| T_inside | Indoor air temperature | INPUT | Indoor air temperature |
| T_outside | Outdoor air temperature | INPUT | Outdoor air temperature |
| R_si | Interior surface thermal resistance | INPUT | Interior surface thermal resistance |
| R_se | Exterior surface thermal resistance | INPUT | Exterior surface thermal resistance |
| R_g1 | Thermal resistance of first glass pane | INPUT | Thermal resistance of first glass pane |
| R_g2 | Thermal resistance of second glass pane | INPUT | Thermal resistance of second glass pane |
| R_g3 | Thermal resistance of third glass pane | INPUT | Thermal resistance of third glass pane |
| surface_temperature | Inner surface temperature of triple glazing | OUTPUT | Inner surface temperature of triple glazing |
Calculation Steps
- Enter the indoor air temperature in K.
- Enter the outdoor air temperature in K.
- Enter the interior surface thermal resistance in m^2*K/W.
- Enter the exterior surface thermal resistance in m^2*K/W.
- Enter the thermal resistance of first glass pane in m^2*K/W.
- Enter the thermal resistance of second glass pane in m^2*K/W.
- Enter the thermal resistance of third glass pane in m^2*K/W.
- Step 1: Compute inner surface temperature of triple glazing.
- Read the inner surface temperature of triple glazing (K) from the results.
Engineering Summary
Calculate Triple Glazing Inner Surface Temperature Calculator
Frequently Asked Questions
What does this calculator calculate?
The Triple Glazing Inner Surface Temperature Calculator estimates Inner surface temperature of triple glazing based on the input parameters you provide
Why is indoor air temperature important in this calculation?
indoor air temperature is directly proportional to inner surface temperature of triple glazing. When you enter indoor air temperature in K, the calculator uses it in the engineering formula to compute the output
How should I interpret the result inner surface temperature of triple glazing?
The calculator outputs inner surface temperature of triple glazing in K. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Indoor air temperature (K), Outdoor air temperature (K), Interior surface thermal resistance (m^2*K/W), Exterior surface thermal resistance (m^2*K/W), Thermal resistance of first glass pane (m^2*K/W), Thermal resistance of second glass pane (m^2*K/W), Thermal resistance of third glass pane (m^2*K/W). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Airtightness Class to Air Permeability Converter (Building Physics) Calculator
Thermal Bridging Ψ-Value Library Matcher for Building Junctions Calculator
Triple Glazing Inner Surface Temperature for Condensation Risk Assessment Calculator
Triple Glazing Linear Thermal Bridge Heat Flow Rate calculator
Triple Glazing Solar Heat Gain Coefficient (SHGC) Calculator
Triple Glazing U-Value Calculator using Thermal Resistance Summation calculator
Browse More Tools
Explore the full index of engineering calculators on this vertical site.