Quick Answer
Calculate Airtightness Class to Air Permeability Converter (Building Physics)
Calculator
Result Interpretation
Airtightness Class to Air Permeability Converter (Building Physics) Calculator computes Air Permeability at 50 Pa in m³/(h·m²) using the defined engineering formula and the input values provided.
Worked Example
Verified calculation
Given:
- Reference Air Permeability = 3
- Reference Class Index = 3
- Airtightness Class = 3
- Logarithmic Class Step Exponent = 0.5
Expected Result:
- Air Permeability at 50 Pa = 3
Engineering Interpretation:
Under the given input conditions, the calculated result is: Air Permeability at 50 Pa = 3 m³/(h·m²).
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
air permeability at 50 pa = reference air permeability * pow(10.0, (airtightness class - reference class index) * logarithmic class step exponent)Formula family: formula_buildingphysics_airtightness_class_to_air_permeability_converter
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| airtightness_class | Airtightness Class | INPUT | Airtightness Class |
| q50_ref | Reference Air Permeability | INPUT | Reference Air Permeability |
| class_ref | Reference Class Index | INPUT | Reference Class Index |
| class_step_exponent | Logarithmic Class Step Exponent | INPUT | Logarithmic Class Step Exponent |
| air_permeability | Air Permeability at 50 Pa | OUTPUT | Air Permeability at 50 Pa |
| log10_e | log10_e | CONSTANT | log10_e = 0.43429448190325 dimensionless |
Calculation Steps
- Enter the airtightness class in dimensionless.
- Enter the reference air permeability in m³/(h·m²).
- Enter the reference class index in dimensionless.
- Enter the logarithmic class step exponent in dimensionless.
- Step 1: Compute air permeability at 50 pa.
- Read the air permeability at 50 pa (m³/(h·m²)) from the results.
Engineering Summary
Calculate Airtightness Class to Air Permeability Converter (Building Physics)
Frequently Asked Questions
What does this calculator calculate?
The Airtightness Class to Air Permeability Converter (Building Physics) Calculator estimates Air Permeability at 50 Pa based on the input parameters you provide
Why is airtightness class important in this calculation?
airtightness class is directly proportional to air permeability at 50 pa. When you enter airtightness class in dimensionless, the calculator uses it in the engineering formula to compute the output
How should I interpret the result air permeability at 50 pa?
The calculator outputs air permeability at 50 pa in m³/(h·m²). The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Airtightness Class (dimensionless), Reference Air Permeability (m³/(h·m²)), Reference Class Index (dimensionless), Logarithmic Class Step Exponent (dimensionless). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Thermal Bridging Ψ-Value Library Matcher for Building Junctions Calculator
Triple Glazing Inner Surface Temperature for Condensation Risk Assessment Calculator
Triple Glazing Linear Thermal Bridge Heat Flow Rate calculator
Triple Glazing Solar Heat Gain Coefficient (SHGC) Calculator
Triple Glazing U-Value Calculator using Thermal Resistance Summation calculator
Vapor Barrier Glazing Steady-State Heat Transfer Rate Calculator
Browse More Tools