Quick Answer
The daylight factor distribution mapper for façade zones calculator computes daylight factor distribution value from the input values you provide.
Calculator
Need Equipment or a Supplier for This Project?
Use your calculation result to continue with equipment selection, supplier discovery, engineering support, or project evaluation.
Find Engineering Solutions →Result Interpretation
Daylight Factor Distribution Mapper for Façade Zones calculator computes Daylight factor distribution value in dimensionless using the defined engineering formula and the input values provided. Daylight factor distribution value is expressed in dimensionless. No universal acceptance threshold is defined by this calculator.
Worked Example
Verified calculation
Given:
- Visible transmittance of glazing = 0.65
- Window area = 12
- Angle of incidence between sky dome centroid vector and façade normal = 0.785398
- Façade zone projected area (vertical projection) = 15
Expected Result:
- Daylight factor distribution value = 23.570229890866
Engineering Interpretation:
Under the given input conditions, the calculated result is: Daylight factor distribution value = 23.570229890866 dimensionless.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from deterministically validated test cases.
Formula / Method
daylight factor distribution value = (0.5 * visible transmittance of glazing * window area * cos(angle of incidence between sky dome centroid vector and façade normal)) / (vertical projection * 0.0078)Daylight factor distribution value.
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| T_vis | Visible transmittance of glazing | INPUT | Visible transmittance of glazing |
| A_win | Window area | INPUT | Window area |
| theta_inc | Angle of incidence between sky dome centroid vector and façade normal | INPUT | Angle of incidence between sky dome centroid vector and façade normal |
| A_zone | Façade zone projected area (vertical projection) | INPUT | Façade zone projected area (vertical projection) |
| result | Daylight factor distribution value | OUTPUT | Daylight factor distribution value |
Calculation Steps
- Enter the visible transmittance of glazing in dimensionless.
- Enter the window area in m².
- Enter the angle of incidence between sky dome centroid vector and façade normal in rad.
- Enter the façade zone projected area (vertical projection) in m².
- Step 1: Compute daylight factor distribution value.
- Read the daylight factor distribution value (dimensionless) from the results.
Frequently Asked Questions
What does this calculator calculate?
The Daylight Factor Distribution Mapper for Façade Zones calculator estimates Daylight factor distribution value based on the input parameters you provide
Why is visible transmittance of glazing important in this calculation?
visible transmittance of glazing is directly proportional to daylight factor distribution value. When you enter visible transmittance of glazing in dimensionless, the calculator uses it in the engineering formula to compute the output
How should I interpret the result daylight factor distribution value?
The calculator outputs daylight factor distribution value in dimensionless. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Visible transmittance of glazing (dimensionless), Window area (m²), Angle of incidence between sky dome centroid vector and façade normal (rad), Façade zone projected area (vertical projection) (m²). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Vapor Diffusion Resistance Factor (μ) from Sd-value and Material Thickness calculator
Vapor Diffusion Resistance Balance Thickness Calculator
Air Permeability to Airtightness Class Converter calculator
Airtightness Class to Air Permeability Converter (Building Physics) Calculator
Airtightness Performance Gap Diagnostic for Retrofit Projects calculator
Dynamic Air Permeability to ACH50 Converter for Infiltration-Driven Moisture Load Estimation calculator
Browse More Tools
Explore the full index of engineering calculators on this vertical site.