Quick Answer
Calculate Vapor Barrier Glazing Steady-State Heat Transfer Rate Calculator
Calculator
Result Interpretation
Vapor Barrier Glazing Steady-State Heat Transfer Rate Calculator computes Steady-state heat transfer rate per unit area in W/m^2 using the defined engineering formula and the input values provided.
Worked Example
Verified calculation
Given:
- Exterior surface thermal resistance = 0.04
- Interior surface thermal resistance = 0.13
- Thermal resistance of gas-filled cavity (including vapor barrier effect on convection) = 0.18
- Thermal resistance of inner glass pane = 0.0028
- Thermal resistance of outer glass pane = 0.0028
- Indoor air temperature = 294.15
- Outdoor air temperature = 273.15
Expected Result:
- Steady-state heat transfer rate per unit area = 59.055118110236
Engineering Interpretation:
Under the given input conditions, the calculated result is: Steady-state heat transfer rate per unit area = 59.055118110236 W/m^2.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
steady-state heat transfer rate per unit area = (indoor air temperature - outdoor air temperature) / (interior surface thermal resistance + thermal resistance of inner glass pane + including vapor barrier effect on convection + thermal resistance of outer glass pane + exterior surface thermal resistance)Formula family: formula_buildingphysics_vapor_barrier_glazing_heat_transfer_calculator
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| T_inside | Indoor air temperature | INPUT | Indoor air temperature |
| T_outside | Outdoor air temperature | INPUT | Outdoor air temperature |
| R_si | Interior surface thermal resistance | INPUT | Interior surface thermal resistance |
| R_se | Exterior surface thermal resistance | INPUT | Exterior surface thermal resistance |
| R_glass1 | Thermal resistance of inner glass pane | INPUT | Thermal resistance of inner glass pane |
| R_glass2 | Thermal resistance of outer glass pane | INPUT | Thermal resistance of outer glass pane |
| R_gap | Thermal resistance of gas-filled cavity (including vapor barrier effect on convection) | INPUT | Thermal resistance of gas-filled cavity (including vapor barrier effect on convection) |
| heat_transfer_rate | Steady-state heat transfer rate per unit area | OUTPUT | Steady-state heat transfer rate per unit area |
Calculation Steps
- Enter the indoor air temperature in K.
- Enter the outdoor air temperature in K.
- Enter the interior surface thermal resistance in m^2·K/W.
- Enter the exterior surface thermal resistance in m^2·K/W.
- Enter the thermal resistance of inner glass pane in m^2·K/W.
- Enter the thermal resistance of outer glass pane in m^2·K/W.
- Enter the thermal resistance of gas-filled cavity (including vapor barrier effect on convection) in m^2·K/W.
- Step 1: Compute steady-state heat transfer rate per unit area.
- Read the steady-state heat transfer rate per unit area (W/m^2) from the results.
Engineering Summary
Calculate Vapor Barrier Glazing Steady-State Heat Transfer Rate Calculator
Frequently Asked Questions
What does this calculator calculate?
The Vapor Barrier Glazing Steady-State Heat Transfer Rate Calculator estimates Steady-state heat transfer rate per unit area based on the input parameters you provide
Why is indoor air temperature important in this calculation?
indoor air temperature is directly proportional to steady-state heat transfer rate per unit area. When you enter indoor air temperature in K, the calculator uses it in the engineering formula to compute the output
How should I interpret the result steady-state heat transfer rate per unit area?
The calculator outputs steady-state heat transfer rate per unit area in W/m^2. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Indoor air temperature (K), Outdoor air temperature (K), Interior surface thermal resistance (m^2·K/W), Exterior surface thermal resistance (m^2·K/W), Thermal resistance of inner glass pane (m^2·K/W), Thermal resistance of outer glass pane (m^2·K/W), Thermal resistance of gas-filled cavity (including vapor barrier effect on convection) (m^2·K/W). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment